Medical

HOME | OUR PEOPLE | MEDICAL | FREE-STANDING MED-GAS DISPENSER | R A C S - System (Mobile Hospital) | PROJECT MANAGEMENT | COFFEE EXPRESS USA | REFERENCES U.S. ARMY EUROPE | FURNITURE | CONTACT US

Specializing In:

- Med Gas Certification:
    - New Construction

    - Annuals

- Also Availiable from Janelco Global Inc:
    - Vacuum Pump Packages
    - Medical Air Compressor Packages
    - Hyperbaric Systems
    - Medical Gas System Consultation
    - Turn-Key Projects
    - Dental Piping Equipment
    - Industrial Gas Systems



Member
A.S.H.E. - N.F.P.A. - A.S.S.E.

Distributors For:

Ohio Medical Products
- pipeline equipment

Allied Healthcare Products - flowmeters, suction regulator

Bay Products - med gas adapters, fittings

BelMed - dental piping products

Craftmark - decals, signage

Precision Medical - med gas adapters, fittings

Western Enterprises - fittings, hoses

Flagship Products:
        - Vacuum Pump Packages using low maintenance "claw" design





- Over 50 years accumulated experience in the med gas field in health care facilities
- Licensed med gas verifier/inspector
- 24/7 response

Medical Gas Systems New Construction Verification Procedure:

The following is an outline of our medical gas pipeline certification procedure and the instrumentation used to perform those tests.

1.  Acquire and verify documentation (mil sheets) of, and visually inspect pipeline to verify use of cleaned and capped copper tubing, cleaned and bagged fittings, correct brazing alloy (BcvP), NF nitrogen, and labeling of pipeline

2.  Verify installer credentials in accordance with NFPA 99-C, Chapter 4
3.  Perform the following tests as required:
    a.  Cross connection test
    b.  Valve test
    c.  Flow test
    d.  Alarm test
    e.  Piping purge test (particular matter) using .45 micron filter @ 3.5 SCFM flow
    f.  Piping purity test, using Miran 203 infrared spectrometer check for:
                >  Total hydrocarbons as methane
                >  halogenated hydrocarbons
    g.  Verify dew point using Hydrodynamics model 8092 pressure dew point monitor
    h.  Final tie-in test and flow
    i.  Operational pressure/flow test using a five inch, calibrated, 100 psi gauge and Dwyer Instuments 1000 Ipm flowmeter
    j.  Oxygen concentration test using MAX O2 oxygen analyzer
    k.  Nitrous oxide concentration testing using Bacharach Model 54-9105 infrared medical gas analyzer
    l.  medical air purity tests:
                >  Carbon monoxide in ppm
                >  Carbon dioxide in ppm
                >  Gaseous hydrocarbons in ppm
                >  Halogenated hydrocarbons in ppm
                >  Dew point using Hydrodynamics model 8092 pressure dew point monitor
    m.  Verify operation of medical gas outlets and related fixtures.

Provide field test reports signed by all parties.  If systems successfully pass inspection, a final report is vertified and distributed.

Annual Med Gas Inspection Procedure

Our annual medical gas system inspection  program is intended to ascertain if your facility's medical gas systems comply with applicable NFPA recommendations. We inspect and test all components of the medical gas systems, from source to final usage points.

Sources:

Oxygen: Inspect and evaluate oxygen supply source. If source is non-hospital owned, supplier representative shall be present to assist in operational verification procedure of system and alarm points.

Other Compressed Med Gases (Nitrogen, Nitrous Oxide, etc):  Inspect and evaluate manifold and control system. Operation verification of bank to bank change over, alarm, pressure switch settings, and function.

Medical Air Compressor:  Inspect and evaluate air compressor.dryer package and intake location, alarms, pressure switch settings, and functions.

Medical Vacuum Pump:  Inspect and evaluate pump package, discharge location, alarms, pressure switch settings and functions.

Medical Gas Distribution System:

Pipeline:  Verify content and flow direction labeling.

Zone Valves:  Inspect and evaluate zone valves for leakage; verify labeling and controlled areas.

Alarms: Verify location and function of alarm pressure switches; operational verification of master and area alarms.

Patient Use Points (outlets/terminals):

Inspect and evaluate outlets, hose reels, ceiling columns, nitrogen control panels, rail systems, etc. for:
    a.  Odor (sniff test)
    b.  Cross connection tests
    c.  Gas concentration (purity) test, using Ceramatex o2 analyzer for oxygen and medical air, and Buchanan 54-9105 nitrous oxide analyzer for nitrous oxide
    d.  Operational pressure test
    e.  Operational flow test
    f.  Piping purge test (particulate matter), using .45 micron filter @ 3.5 SCFM flow
    g.  Operational verification of outlets/terminals (latching, leaks, etc.)
    h.  Medical air shall be tested in selected locations for:
        1.  Dewpoint, using newport 8092 Dewpoint Monitor
        2.  Carbon Monoxide in ppm
        3.  Carbon Dioxide in ppm
        4.  Gaseous Hydrocarbons in ppm
        5.  Halogenated hydrocarbons in ppm, using Miran 203 Infrared Spectrometer.


A confidential detailed report will be compiled and forwarded to hospital administration and engineering. Maintenance with any deficiencies noted. Corrective procedures will be provided upon request.

CODE        NAICS Code's Description
325120              Industrial Gas Manufacturing
333411              Air Purification Equiptment Manufacturing
339111              Laboratory Apparatus and Furniture Manufacturing
339112              Surgical and Medical Instrument Manufacturing
492210              Local Messengers and Local Delivery
493110              General Warehousing and Storage

Click here to learn more about Medical Gas Alternatives.

For more information on Janelco Global Inc's medical services and supplies, please contact Francis DeGeorge at francis@janelco.net or 504-883-0934.

If you are having problems viewing this site, please contact
info@janelco.net or ed@janelco.net .

Enter supporting content here